Offline).
Linecard slot 1: No card diags executed yet (Card
Offline).
Linecard slot 2: No card diags executed yet (Card
Offline).
Linecard slot 3: No card diags executed yet (Card
Offline).
----------------------------
Example: After
offline
diagnostics are
run on a switch
Dell# show diag information
Diag information:
Diag software image version:
9.5(0.1)
----------------------------
Linecard slot 0: Card diags are done (Card Offline).
Linecard slot 1: Card diags are done (Card Offline).
Linecard slot 2: Card diags are done (Card Offline).
Linecard slot 3: Card diags are done (Card Offline).
----------------------------
show diag testcase
Display the offline diagnostic tests available for the Z9500 CPUs at each level.
Syntax
show diag testcase {all | {{cp | rp | linecard}
unit-id
}
[alllevels | level0 | level1 | level2]
Parameters
all
Enter the keyword
all
to display the complete suite of
offline diagnostic tests available on the Z9500.
cp
unit-id
Enter the
cp
unit-id
parameters to display only the offline
diagnostic tests available on the Control Processor CPU. The
Control Processor CPU ID is 0.
rp
unit-id
Enter the
rp
unit-id
parameters to display only the offline
diagnostic tests available on the Route Processor CPU. The
Route Processor CPU ID is 0.
linecard
unit-id
Enter the
linecard
unit-id
parameters to display only
the offline diagnostic tests available for a specified line card.
The range of line-card CPU IDs is from 0 to 2. Each line-card
CPU processes packets on the corresponding Z9500 line
card; for example, line-card CPU 1 processes packets on line
card 1.
alllevels
Enter the keyword
alllevels
to display the the complete
set of offline diagnostic tests.
level0
Enter the keyword
level0
to display only the Level 0
diagnostic tests. Level 0 diagnostics check for the presence
of various components and perform essential path
verifications. In addition, they verify the identification
registers of the components on the board.