• For a Tunnel interface, enter the keyword
tunnel
then
the tunnel ID. The range is from 1 to 16383.
• For a VLAN interface, enter the keyword
vlan
then a
number from 1 to 4094.
Defaults
none
Command
Modes
CONFIGURATION
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.7(0.0)
Introduced on the S6000-ON.
9.0.2.0
Introduced on the S6000.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
8.5.1.0
Added support for 4-port 40G line cards on ExaScale.
8.2.1.0
Added support for 4093 VLANs on E-Series ExaScale. Prior
releases supported 2094.
8.1.1.0
Introduced on the E-Series ExaScale.
7.6.1.0
Introduced on the S-Series.
7.5.1.0
Introduced on the C-Series.
pre-Version
6.1.1.0
Introduced on the E-Series.
Example (Single
Range)
This example shows how to define an interface range macro named test. Execute
the
show running-config
command to display the macro definition.
Dell(config)# define interface-range test tengigabitethernet
1/1 -3,
tengigabitethernet 5/1 -47, tengigabitethernet 13/1 -89
Dell# show running-config | grep define
define interface-range test tengigabitethernet 1/1 -3,
tengigabitethernet 5/1 -47,
tengigabitethernet 13/1 - 89
Dell(config)#interface range macro test
Dell(config-if-range-te-1/1-3,te-5/1-47,te-13/1-89)#
Related
Commands
interface range
– configures a range of command (bulk configuration)
850
Interfaces