Version 8.3.7.0
Introduced on the S4810.
Version 8.3.1.0
Introduced the
verbose
option.
Version 7.7.1.0
Introduced on the S-Series.
Related
Commands
offline stack-unit
— bring a switch offline to run diagnostic tests.
online stack-unit
— reload the system after running offline diagnostic tests.
offline system
Place the switch in the offline state in order to run diagnostic tests.
Z9500
Syntax
offline system
Defaults
none
Command
Modes
EXEC Privilege
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.2(1.0)
Introduced on the Z9500.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
8.2.1.0
Added a warning message to the off-line diagnostic.
7.7.1.0
Introduced on the S-Series.
Usage
Information
To run diagnostic tests on an offline switch, use the
diag
command.
The system reboots when offline diagnostics complete. This reboot is an automatic
process. A warning message appears when the
offline system
command is
implemented.
Warning - Diagnostic execution will cause system to reboot
after completion of diags.
Proceed with Offline-Diags [confirm yes/no]:y
Debugging and Diagnostics