Page 1: ...Kramer Electronics Ltd USER MANUAL Model VP 311DVI Automatic DVI Audio Switcher im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Page 2: ...3 Control Configuration via the Ethernet Port 12 6 Technical Specifications 13 Figures Figure 1 VP 311DVI Automatic DVI Audio Switcher 5 Figure 2 Connecting the VP 311DVI Automatic DVI Audio Switcher 7 Figure 3 VP 311DVI DIP switches 8 Figure 4 Connecting the Contact Closure Remote Control PINS 9 Figure 5 Crossed Cable RS 232 Connection 10 Figure 6 Straight Cable RS 232 Connection with a Null Mode...

Page 3: ...tter including the required battery and a separate user manual3 This user manual3 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resolution DVI cables4 1 GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers...

Page 4: ...R SIMPLE CREATIVE TECHNOLOGY 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Page 5: ...ront panel INPUT SELECT buttons but once the selected video signal is lost the machine automatically switches to the highest priority input according to the input priority setup1 The VP 311DVI is housed in a desktop sized enclosure and is 12V DC fed The VP 311DVI will switch back to the primary input when a DVI signal is detected on that input Control the VP 311DVI using the front panel buttons or...

Page 6: ...er network On the Internet a node or stopping point can be either a gateway node or a host end point node IP Address A 32 binary digit number that identifies each sender or receiver within a network via a particular server or workstation of data HTML pages or e mails that is sent in packets across the Internet Every device connected to an IP network must have a unique IP address This address is us...

Page 7: ...balanced stereo audio inputs from 1 to 3 7 S PDIF OUT RCA Connector Connect to a digital audio S PDIF output 8 IN RCA Connectors Connect to digital audio S PDIF inputs from 1 to 3 9 RS 232 DB 9F Port Connect to the PC or the Remote Controller 10 PRIORITY SETUP DIP switches DIP switches for setup of the machine DIPs 1 2 3 are for setting the signal priorities DIP 4 is for setting to the manual or t...

Page 8: ...ET port see section 5 4 7 If required connect7 5 2 the contact closure remote control PINS see section 8 Connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity 1 You do not need to connect all the inputs When connecting a DVI source to IN 2 if your cable does not fit you can use the customized DVI cable supplied with the package 2 Switch OFF the power...

Page 9: ...he VP 311DVI Automatic DVI Audio Switcher 7 Figure 2 Connecting the VP 311DVI Automatic DVI Audio Switcher im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Page 10: ...al mode switch between channels manually ON automatic mode inputs switch automatically to the output according to the priority setup Inputs 1 2 and 3 can be set in priority according to your needs The VP 311DVI will switch to the secondary input upon loss of the primary input signal and back to the primary input when a signal is detected Table 4 describes the priority setup Table 4 DIP switch Prio...

Page 11: ...ar way to the input buttons For example you may override1 the presently routed input by using the remote control contact closure To do so2 connect the appropriate input number3 pin on the REMOTE terminal block connector to the G Ground pin4 Figure 4 as illustrates DO NOT Connect more than one PIN to the Ground PIN at the same time To route IN 1 to the output temporarily attach PIN 1 to PIN G Groun...

Page 12: ...control is not required for this unit In the rare case where a controller requires hardware flow control short pin 1 to 7 and 8 and pin 4 to 6 on the controller side Method B Figure 6 Connect the RS 232 9 pin D sub port on the unit via a straight flat cable to the null modem adapter and connect the null modem adapter to the RS 232 9 pin D sub port on the PC The straight cable usually contains all ...

Page 13: ...factory configured default IP address After connecting the Ethernet port configure your PC as follows 1 Right click the My Network Places icon on your desktop 2 Select Properties 3 Right click Local Area Connection Properties 4 Select Properties The Local Area Connection Properties window appears 5 Select the Internet Protocol TCP IP and click the Properties Button see Figure 7 Figure 7 Local Area...

Page 14: ...Through Cable You can connect the Ethernet port of the VP 311DVI to the Ethernet port on a network hub or network router via a straight through cable with RJ 45 connectors 5 4 3 Control Configuration via the Ethernet Port To control several units via the Ethernet connect the unit via the Ethernet port to the LAN port of your PC Use your PC initially to configure the settings see section 5 4 im Ver...

Page 15: ...audio on a 5 pin detachable terminal block DATA RATE Up to 1 65Gbps POWER SOURCE 12V DC 270mA CONTROLS Front panel buttons infrared remote control transmitter RS 232 Ethernet DIMENSIONS 21 6cm x 16 1cm x 4 4cm 8 5 x 6 3 x 1 7 W D H WEIGHT 1 2kg 2 6lbs approx ACCESSORIES Power supply DVI male to male cable IR remote control transmitter null modem adapter Windows based Configuration Manager Ethernet...

Page 16: ...ailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct claims must bepresentedtothe carrier v Removalorinstallationoftheproduct vi Anyothercause whichdoes not relateto aproduct defect vii Cartons equipment enclosures cables or accessoriesusedinconjunctionwiththeproduct 1 Removal orinstallationscharges 2 Costs of ...

Page 17: ...distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Caution Safety Warning Disconnect the unit from the power supply before opening servicing P N 2900 000120 Rev 2 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...