2
Click
(Element Properties).
3
In the Element Properties dialog, click Edit/New.
4
In the Type Properties dialog, select Room Bounding.
5
Click OK twice.
Now you can place rooms in the plan view, using the boundaries defined by room-bounding elements in
the host project and the room-bounding elements in the linked model. See
Creating a Room
on page 913.
Rooms Spanning Floors or Levels
Rooms can span multiple floors or levels. For example, a building that has a public space or atrium that
spans multiple floors can be represented with a single room. Use the Upper Limit and Limit Offset parameters
to define the upper boundary of the room. See
Defining the Upper Boundary of a Room
on page 930.
Upgrading Rooms from Earlier Versions
The following sections contain information about recent enhancements to rooms.
Upgrading from Revit 2008 to Revit 2009
In Revit 2009, the algorithm for computing room volumes is further enhanced to improve accuracy. In
addition, for the purpose of estimating HVAC loads, room volumes are now computed to the wall face.
(They are no longer computed to the wall center or wall core.)
As a result, in existing projects that contain rooms, Revit Architecture may show numbers for room volumes
that are different from previous project numbers. These numbers reflect more accurate computations for
room volumes.
Upgrading from earlier versions to Revit 9
As of version 9.0, room calculations use new algorithms to compute room boundaries. These changes, which
make room calculations more robust, may cause changes to rooms that are upgraded from earlier versions.
For example, as of 9.0, crossing walls bound rooms.
If room-related warning messages are displayed during the upgrade process, you can review them later. (Click
Tools menu
➤
Review Warnings, or see
Warnings for Selected Elements
on page 1334.) After upgrading, review
room schedules and tags to make sure they are accurate.
For more information, see
Room-Bounding Elements
on page 917 and
Troubleshooting Rooms
on page 941.
Rooms Spanning Floors or Levels | 921
Содержание 24000-000000-9860 - Revit Architecture - PC
Страница 1: ...Revit Architecture 2009 User s Guide April 2008 240A1 050000 PM02A ...
Страница 4: ......
Страница 56: ...18 ...
Страница 116: ...78 Chapter 3 Revit Essentials ...
Страница 172: ...134 Chapter 4 ProjectViews ...
Страница 178: ...Schedule with Grid Lines Schedule with Grid Lines and an Outline 140 Chapter 4 ProjectViews ...
Страница 352: ...Defining the first scale vector Defining the second scale vector 314 Chapter 7 Editing Elements ...
Страница 554: ...516 ...
Страница 739: ...Curtain wall Curtain Grid Curtain Walls Curtain Grids and Mullions 701 ...
Страница 898: ...Pile caps with multiple piles Rectangular and triangular pile caps 860 Chapter 12 Working with Structural Components ...
Страница 1004: ...966 ...
Страница 1136: ...1098 ...
Страница 1226: ...1188 ...
Страница 1250: ...1212 ...
Страница 1276: ...1238 Chapter 20 Design Options ...
Страница 1310: ...1272 ...
Страница 1366: ...1328 ...
Страница 1406: ...1368 ...