PWM Registers
1483
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Pulse Width Modulator (PWM)
Table 21-23. PWMnGENB Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
9-8
ACTCMPBU
R/W
0x0
Action for Comparator B Up This field specifies the action to be
taken when the counter matches comparator B while counting up.
This action can only occur when the MODE bit in the PWMnCTL
register is set.
0x0 = Do nothing
0x1 = Invert pwmB
0x2 = Drive pwmB low
0x3 = Drive pwmB high
7-6
ACTCMPAD
R/W
0x0
Action for Comparator A Down This field specifies the action to be
taken when the counter matches comparator A while counting down.
0x0 = Do nothing
0x1 = Invert pwmB
0x2 = Drive pwmB low
0x3 = Drive pwmB high
5-4
ACTCMPAU
R/W
0x0
Action for Comparator A Up This field specifies the action to be
taken when the counter matches comparator A while counting up.
This action can only occur when the MODE bit in the PWMnCTL
register is set.
0x0 = Do nothing
0x1 = Invert pwmB
0x2 = Drive pwmB low
0x3 = Drive pwmB high
3-2
ACTLOAD
R/W
0x0
Action for Counter= LOAD This field specifies the action to be taken
when the counter matches the load value.
0x0 = Do nothing
0x1 = Invert pwmB
0x2 = Drive pwmB low
0x3 = Drive pwmB high
1-0
ACTZERO
R/W
0x0
Action for Counter=0 This field specifies the action to be taken when
the counter is 0.
0x0 = Do nothing
0x1 = Invert pwmB
0x2 = Drive pwmB low
0x3 = Drive pwmB high