CAN Registers
819
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Controller Area Network (CAN) Module
11.4.12 CANIFnARB1 Register [reset = 0x0]
CAN IF1 Arbitration 1 (CANIF1ARB1), offset 0x030
CAN IF2 Arbitration 1 (CANIF2ARB1), offset 0x090
These registers hold the identifiers for acceptance filtering.
CANIFnARB1 is shown in
and described in
Return to
Figure 11-16. CANIFnARB1 Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
ID
R-0x0
R/W-0x0
Table 11-19. CANIFnARB1 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
RESERVED
R
0x0
15-0
ID
R/W
0x0
Message Identifier.
This bit field is used with the ID field in the CANIFnARB2 register to
create the message identifier.
When using a 29-bit identifier, bits 15:0 of the CANIFnARB1 register
are [15:0] of the ID, while bits 12:0 of the CANIFnARB2 register are
[28:16] of the ID.
When using an 11-bit identifier, these bits are not used.