![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 1085](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781085.webp)
MII Management (EPHY) Registers
1085
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Ethernet Controller
Table 15-129. EPHYLEDCFG Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
3-0
LED0
R/W
0x0
LED0 Configuration. The following encodings are used to program
the specific function desired for the LED.
0x0 = Link OK
0x1 = RX/TX Activity
0x2 = TX Activity
0x3 = RX Activity
0x4 = Collision
0x5 = 100-Base TX
0x6 = 10-Base TX
0x7 = Full Duplex
0x8 = Link OK/Blink on TX/RX Activity
0x9 = Reserved
0xA = Reserved
0xB = Reserved
0xC = Reserved
0xD = Reserved
0xE = Reserved
0xF = Reserved