MII Management (EPHY) Registers
1047
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Ethernet Controller
15.7.1 EPHYBMCR Register (Address = 0x0) [reset = 0x3100]
Ethernet PHY Basic Mode Control - MR0 (EPHYBMCR)
This register describes the basic mode controls available to the EPHY. The reset state of the ANEN bit is
controlled by the EMACPC register.
EPHYBMCR is shown in
and described in
Return to
Figure 15-89. EPHYBMCR Register
15
14
13
12
11
10
9
8
MIIRESET
MIILOOPBK
SPEED
ANEN
PWRDWN
ISOLATE
RESTARTAN
DUPLEXM
R/W-0x0
R/W-0x0
R/W-0x1
R/W-0x1
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x1
7
6
5
4
3
2
1
0
COLLTST
RESERVED
R/W-0x0
R-0x0
Table 15-101. EPHYBMCR Register Field Descriptions
Bit
Field
Type
Reset
Description
15
MIIRESET
R/W
0x0
MII Register reset. Writing a 1 to this bit resets the contents of the
MII-related registers: EPHYBMCR (0x000) EPHYANA (0x004) and
EPHYANNPTR (0x007). When the reset operation is done, this bit is
cleared to 0 automatically.
0x0 = Normal operation.
0x1 = Initiate MII Reset / Reset in Process.
14
MIILOOPBK
R/W
0x0
MII Loopback. When MII loopback mode is activated, the transmitter
data presented on MII TXD is looped back to MII RXD internally.
0x0 = Normal operation.
0x1 = MII Loopback enabled.
13
SPEED
R/W
0x1
Speed Select. When auto-negotiation is disabled writing to this bit
allows the port speed to be selected.
0x0 = 10Mbs
0x1 = 100Mbs
12
ANEN
R/W
0x1
Auto-Negotiate Enable.
0x0 = Auto-Negotiation Disabled. The SPEED bit and the DUPLEXM
bit determine the port speed and duplex mode.
0x1 = Auto-Negotiation Enabled. The SPEED bit and the DUPLEXM
bit of this register are ignored when this bit is set.
11
PWRDWN
R/W
0x0
Power Down. Setting this bit powers down the PHY. Only minimal
register functionality is enabled during the power down condition.
0x0 = Normal operation
0x1 = Power-down modes are enabled: General Power Down Mode,
Active Sleep Mode and Passive Sleep Mode (see Ethernet PHY
Specific Control (EPHYSCR) register, offset 0x011.
10
ISOLATE
R/W
0x0
Port Isolate.
0x0 = Normal operation.
0x1 = Isolates the Port from the MII with the exception of the serial
management.
9
RESTARTAN
R/W
0x0
Restart Auto-Negotiation.
0x0 = Normal operation.
0x1 = Auto-Negotiation process is re-initiated. If Auto-Negotiation is
disabled (ANEN = 0), this bit is ignored. This bit is self-clearing and
returns a value of 1 until Auto-Negotiation is initiated, whereupon it
self-clears. Operation of the Auto-Negotiation process is not affected
by the management entity clearing this bit.