![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 770](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578770.webp)
ADC Registers
770
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
10.5.30 ADCSSCTL3 Register (Offset = 0xA4) [reset = 0x0]
ADC Sample Sequence Control 3 (ADCSSCTL3)
This register contains the configuration information for a sample executed with Sample Sequencer 3. This
register is 4 bits wide and contains information for one possible sample. See the ADCSSCTL0 register in
for detailed bit descriptions.
NOTE:
When configuring a sample sequence in this register, the END0 bit must be set.
ADCSSCTL3 is shown in
and described in
Return to
Figure 10-44. ADCSSCTL3 Register
31
30
29
28
27
26
25
24
RESERVED
R-0x0
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
RESERVED
R-0x0
7
6
5
4
3
2
1
0
RESERVED
TS0
IE0
END0
D0
R-0x0
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
Table 10-39. ADCSSCTL3 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-4
RESERVED
R
0x0
3
TS0
R/W
0x0
1st Sample Temp Sensor Select.
0x0 = The input pin specified by the ADCSSMUXn register is read
during the first sample of the sample sequence.
0x1 = The temperature sensor is read during the first sample of the
sample sequence.
2
IE0
R/W
0x0
Sample Interrupt Enable.
It is legal to have multiple samples within a sequence generate
interrupts.
0x0 = The raw interrupt is not asserted to the interrupt controller.
0x1 = The raw interrupt signal (INR0 bit) is asserted at the end of
this sample's conversion. If the MASK0 bit in the ADCIM register is
set, the interrupt is promoted to the interrupt controller.
1
END0
R/W
0x0
End of Sequence.
This bit must be set before initiating a single sample sequence.
0x0 = Sampling and conversion continues.
0x1 = This is the end of sequence.
0
D0
R/W
0x0
Sample Differential Input Select.
Because the temperature sensor does not have a differential option,
this bit must not be set when the TS0 bit is set.
0x0 = The analog inputs are not differentially sampled.
0x1 = The analog input is differentially sampled. The corresponding
ADCSSMUXn nibble must be set to the pair number "i", where the
paired inputs are "2i and 2i+1".