ADC Registers
777
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
Table 10-45. ADCDCRIC Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
6
DCINT6
W
0x0
Digital Comparator Interrupt 6.
When the interrupt has been cleared, this bit is automatically
cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when
starting a new sequence so that stale data is not used.
0x0 = No effect
0x1 = Resets the Digital Comparator 6 interrupt unit to its initial
conditions.
5
DCINT5
W
0x0
Digital Comparator Interrupt 5.
When the interrupt has been cleared, this bit is automatically
cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when
starting a new sequence so that stale data is not used.
0x0 = No effect
0x1 = Resets the Digital Comparator 5 interrupt unit to its initial
conditions.
4
DCINT4
W
0x0
Digital Comparator Interrupt 4.
When the interrupt has been cleared, this bit is automatically
cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when
starting a new sequence so that stale data is not used.
0x0 = No effect
0x1 = Resets the Digital Comparator 4 interrupt unit to its initial
conditions.
3
DCINT3
W
0x0
Digital Comparator Interrupt 3.
When the interrupt has been cleared, this bit is automatically
cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when
starting a new sequence so that stale data is not used.
0x0 = No effect
0x1 = Resets the Digital Comparator 3 interrupt unit to its initial
conditions.
2
DCINT2
W
0x0
Digital Comparator Interrupt 2.
When the interrupt has been cleared, this bit is automatically
cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when
starting a new sequence so that stale data is not used.
0x0 = No effect
0x1 = Resets the Digital Comparator 2 interrupt unit to its initial
conditions.
1
DCINT1
W
0x0
Digital Comparator Interrupt 1.
When the interrupt has been cleared, this bit is automatically
cleared.
Because the digital comparators use the current and previous ADC
conversion values to determine when to assert the interrupt, it is
important to reset the digital comparator to initial conditions when
starting a new sequence so that stale data is not used.
0x0 = No effect
0x1 = Resets the Digital Comparator 1 interrupt unit to its initial
conditions.