System Control Registers
372
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
System Control
4.2.128 DCGCTIMER Register (Offset = 0x804) [reset = 0x00]
16/32-Bit General-Purpose Timer Deep-Sleep Mode Clock Gating Control (DCGCTIMER)
The DCGCTIMER register lets software enable and disable 16/32-bit timer modules in deep-sleep mode.
When enabled, a module is provided a clock. When disabled, the clock is disabled to save power.
NOTE:
This register controls the clocking for the timer modules.
DCGCTIMER is shown in
and described in
Return to
Figure 4-134. DCGCTIMER Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RESERVED
D7
D6
D5
D4
D3
D2
D1
D0
R-0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
Table 4-141. DCGCTIMER Register Field Descriptions
Bit
Field
Type
Reset
Description
31-8
RESERVED
R
0x0
7
D7
R/W
0x0
16/32-Bit General-Purpose Timer 7 Deep-Sleep Mode Clock Gating
Control
0x0 = 16/32-bit general-purpose timer module 7 is disabled in deep-
sleep mode.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 7 in deep-sleep mode.
6
D6
R/W
0x0
16/32-Bit General-Purpose Timer 6 Deep-Sleep Mode Clock Gating
Control
0x0 = 16/32-bit general-purpose timer module 6 is disabled in deep-
sleep mode.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 6 in deep-sleep mode.
5
D5
R/W
0x0
16/32-Bit General-Purpose Timer 5 Deep-Sleep Mode Clock Gating
Control
0x0 = 16/32-bit general-purpose timer module 5 is disabled in deep-
sleep mode.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 5 in deep-sleep mode.
4
D4
R/W
0x0
16/32-Bit General-Purpose Timer 4 Deep-Sleep Mode Clock Gating
Control
0x0 = 16/32-bit general-purpose timer module 4 is disabled in deep-
sleep mode.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 4 in deep-sleep mode.
3
D3
R/W
0x0
16/32-Bit General-Purpose Timer 3 Deep-Sleep Mode Clock Gating
Control
0x0 = 16/32-bit general-purpose timer module 3 is disabled in deep-
sleep mode.
0x1 = Enable and provide a clock to 16/32-bit general-purpose timer
module 3 in deep-sleep mode.