Initialization and Configuration
1509
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
1-Wire Master Module
7. Write to the ONEWIRECS register to set the RST bit and configure the OP (operation) and SZ fields.
When configuring all three bit fields, the reset is performed first, followed by the operation (unless an
error occurs) and then any interrupt triggers.
8. If normal interrupts are generated (for example, OPC and RST), clear these interrupts and read the
ONEWIREDATR register if a read or read/write transaction occurred.
9. If the 1-Wire master has more data to write and/or read for the same command, repeat the previous
two steps but without setting the RST bit. If a new command is required, repeat the previous two steps
including the reset enable.