![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 307](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578307.webp)
System Control Registers
307
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
System Control
4.2.70 SRUART Register (Offset = 0x518) [reset = 0x00]
Universal Asynchronous Receiver/Transmitter Software Reset (SRUART)
The SRUART register lets software reset the available UART modules.
A peripheral is reset by software using a simple 2-step process:
1. Software sets a bit (or bits) in the SRUART register. While the SRUART bit is 1, the peripheral is held
in reset.
2. Software completes the reset process by clearing the SRUART bit.
There may be latency from the clearing of the SRUART bit to when the peripheral is ready for use.
Software should check the corresponding PRUART bit to verify that the UART module registers are ready
to be accessed.
NOTE:
Use this register to reset the UART modules.
SRUART is shown in
and described in
.
Return to
Figure 4-76. SRUART Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
RESERVED
R7
R6
R5
R4
R3
R2
R1
R0
R-0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
R/W-
0x0
Table 4-83. SRUART Register Field Descriptions
Bit
Field
Type
Reset
Description
31-8
RESERVED
R
X
7
R7
R/W
0x0
UART Module 7 Software Reset
0x0 = UART module 7 is not reset.
0x1 = UART module 7 is reset.
6
R6
R/W
0x0
UART Module 6 Software Reset
0x0 = UART module 6 is not reset.
0x1 = UART module 6 is reset.
5
R5
R/W
0x0
UART Module 5 Software Reset
0x0 = UART module 5 is not reset.
0x1 = UART module 5 is reset.
4
R4
R/W
0x0
UART Module 4 Software Reset
0x0 = UART module 4 is not reset.
0x1 = UART module 4 is reset.
3
R3
R/W
0x0
UART Module 3 Software Reset
0x0 = UART module 3 is not reset.
0x1 = UART module 3 is reset.
2
R2
R/W
0x0
UART Module 2 Software Reset
0x0 = UART module 2 is not reset.
0x1 = UART module 2 is reset.
1
R1
R/W
0x0
UART Module 1 Software Reset
0x0 = UART module 1 is not reset.
0x1 = UART module 1 is reset.