USB Registers
1708
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Universal Serial Bus (USB) Controller
Figure 27-10. USBIS Register (OTG B / Device)
7
6
5
4
3
2
1
0
RESERVED
DISCON
RESERVED
SOF
RESET
RESUME
SUSPEND
R-0x0
R-0x0
R-0x0
R-0x0
R-0x0
R-0x0
R-0x0
Table 27-15. USBIS Register Field Descriptions (OTG B / Device)
Bit
Field
Type
Reset
Description
7-6
RESERVED
R
0x0
5
DISCON
R
0x0
Session Disconnect.
0x0 = No interrupt.
0x1 = The device has been disconnected from the host.
4
RESERVED
R
0x0
3
SOF
R
0x0
Start of Frame.
0x0 = No interrupt.
0x1 = A new frame has started.
2
RESET
R
0x0
RESET Signaling Detected.
0x0 = No interrupt.
0x1 = RESET signaling has been detected on the bus.
1
RESUME
R
0x0
RESUME Signaling Detected.
This interrupt can only be used if the USB controller's system clock
is enabled.
If the user disables the clock programming, the USBDRRIS,
USBDRIM, and USBDRISC registers should be used.
0x0 = No interrupt.
0x1 = RESUME signaling has been detected on the bus while the
USB controller is in SUSPEND mode.
0
SUSPEND
R
0x0
SUSPEND Signaling Detected.
0x0 = No interrupt.
0x1 = SUSPEND signaling has been detected on the bus.