![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 1577](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781577.webp)
QEI Registers
1577
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Quadrature Encoder Interface (QEI)
24.5.3 QEIPOS Register (Offset = 0x8) [reset = 0x0]
QEI Position (QEIPOS)
This register contains the current value of the position integrator. The value is updated by the status of the
QEI phase inputs and can be set to a specific value by writing to it.
QEIPOS is shown in
and described in
Return to
Figure 24-6. QEIPOS Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
POSITION
R/W-0x0
Table 24-5. QEIPOS Register Field Descriptions
Bit
Field
Type
Reset
Description
31-0
POSITION
R/W
0x0
Current Position Integrator Value. The current value of the position
integrator.