ADC Registers
737
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
10.5.9 ADCSSPRI Register (Offset = 0x20) [reset = 0x3210]
ADC Sample Sequencer Priority (ADCSSPRI)
This register sets the priority for each of the sample sequencers. Out of reset, Sequencer 0 has the
highest priority, and Sequencer 3 has the lowest priority. When reconfiguring sequence priorities, each
sequence must have a unique priority for the ADC to operate properly.
ADCSSPRI is shown in
and described in
Return to
Figure 10-23. ADCSSPRI Register
31
30
29
28
27
26
25
24
RESERVED
R-0x0
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
RESERVED
SS3
RESERVED
SS2
R-0x0
R/W-0x3
R-0x0
R/W-0x2
7
6
5
4
3
2
1
0
RESERVED
SS1
RESERVED
SS0
R-0x0
R/W-0x1
R-0x0
R/W-0x0
Table 10-16. ADCSSPRI Register Field Descriptions
Bit
Field
Type
Reset
Description
31-14
RESERVED
R
0x0
13-12
SS3
R/W
0x3
SS3 Priority.
This field contains a binary-encoded value that specifies the priority
encoding of Sample Sequencer 3.
A priority encoding of 0x0 is highest and 0x3 is lowest.
The priorities assigned to the sequencers must be uniquely mapped.
The ADC may not operate properly if two or more fields are equal.
11-10
RESERVED
R
0x0
9-8
SS2
R/W
0x2
SS2 Priority.
This field contains a binary-encoded value that specifies the priority
encoding of Sample Sequencer 2.
A priority encoding of 0x0 is highest and 0x3 is lowest.
The priorities assigned to the sequencers must be uniquely mapped.
The ADC may not operate properly if two or more fields are equal.
7-6
RESERVED
R
0x0
5-4
SS1
R/W
0x1
SS1 Priority.
This field contains a binary-encoded value that specifies the priority
encoding of Sample Sequencer 1.
A priority encoding of 0x0 is highest and 0x3 is lowest.
The priorities assigned to the sequencers must be uniquely mapped.
The ADC may not operate properly if two or more fields are equal.
3-2
RESERVED
R
0x0
1-0
SS0
R/W
0x0
SS0 Priority.
This field contains a binary-encoded value that specifies the priority
encoding of Sample Sequencer 0.
A priority encoding of 0x0 is highest and 0x3 is lowest.
The priorities assigned to the sequencers must be uniquely mapped.