![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 1282](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781282.webp)
GPTM Registers
1282
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
General-Purpose Timers
18.5.5 GPTMSYNC Register (Offset = 0x10) [reset = 0x0]
GPTM Synchronize (GPTMSYNC)
NOTE:
This register is only implemented on GPTM Module 0 only.
This register allows software to synchronize a number of timers.
GPTMSYNC is shown in
and described in
.
Return to
Figure 18-13. GPTMSYNC Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
RESERVED
R-0x0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
SYNCT7
SYNCT6
SYNCT5
SYNCT4
SYNCT3
SYNCT2
SYNCT1
SYNCT0
WO-0x0
WO-0x0
WO-0x0
WO-0x0
WO-0x0
WO-0x0
WO-0x0
WO-0x0
Table 18-16. GPTMSYNC Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
RESERVED
R
0x0
15-14
SYNCT7
W
0x0
Synchronize GPTM Timer 7
0x0 = GPT7 is not affected.
0x1 = A timeout event for Timer A of GPTM7 is triggered.
0x2 = A timeout event for Timer B of GPTM7 is triggered.
0x3 = A timeout event for both Timer A and Timer B of GPTM7 is
triggered.
13-12
SYNCT6
W
0x0
Synchronize GPTM Timer 6
0x0 = GPTM6 is not affected.
0x1 = A timeout event for Timer A of GPTM6 is triggered.
0x2 = A timeout event for Timer B of GPTM6 is triggered.
0x3 = A timeout event for both Timer A and Timer B of GPTM6 is
triggered.
11-10
SYNCT5
W
0x0
Synchronize GPTM Timer 5
0x0 = GPTM5 is not affected.
0x1 = A timeout event for Timer A of GPTM5 is triggered.
0x2 = A timeout event for Timer B of GPTM5 is triggered.
0x3 = A timeout event for both Timer A and Timer B of GPTM5 is
triggered.
9-8
SYNCT4
W
0x0
Synchronize GPTM Timer 4
0x0 = GPTM4 is not affected.
0x1 = A timeout event for Timer A of GPTM4 is triggered.
0x2 = A timeout event for Timer B of GPTM4 is triggered.
0x3 = A timeout event for both Timer A and Timer B of GPTM4 is
triggered.
7-6
SYNCT3
W
0x0
Synchronize GPTM Timer 3
0x0 = GPTM3 is not affected.
0x1 = A timeout event for Timer A of GPTM3 is triggered.
0x2 = A timeout event for Timer B of GPTM3 is triggered.
0x3 = A timeout event for both Timer A and Timer B of GPTM3 is
triggered.