![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 1328](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781328.webp)
Idle
Write slave address
to I2CMSA
Write data to
I2CMDR
Read I2CMCS
BUSBSY bit = 0?
Write xxx0x011 to
I2CMCS
(see Note)
Read I2CMCS
BUSY bit = 0?
ERROR bit = 0?
ARBLST bit = 1?
Write data to
I2CMDR
Write xxx0x100 to
I2CMCS
(see Note)
Index = n?
Error service
Idle
Write xxx0x001 to
I2CMCS
(see Note)
Write xxx0x101 to
I2CMCS
(see Note)
Read I2CMCS
BUSY bit = 0?
ERROR bit=0?
Idle
Error Service
Sequence may
be omitted in a
single master
system
No
Yes
No
No
Yes
Yes
No
No
Yes
Yes
Yes
No
Yes
No
Functional Description
1328
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Inter-Integrated Circuit (I
2
C) Interface
NOTE: x = application-specific bit
Figure 19-10. Master Transmit of Multiple Data Bytes