![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 768](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578768.webp)
ADC Registers
768
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
10.5.28 ADCSSTSH1 and ADCSSTSH2 Registers [reset = 0x0]
ADC Sample Sequence 1 Sample and Hold Time (ADCSSTSH1), offset 0x07C
ADC Sample Sequence 2 Sample and Hold Time (ADCSSTSH2), offset 0x09C
These registers control the sample period size for each sample step of sequencer 1 and sequencer 2.
Each sample and hold period select specifies the time allocated to the sample and hold circuit as shown
by the encodings in
NOTE:
If sampling the internal temperature sensor, the sample and hold width should be at least 16
ADC clocks (TSHn = 0x4).
Table 10-36. Sample and Hold Width in ADC Clocks
TSHn Encoding
N
SH
0x0
4
0x1
Reserved
0x2
8
0x3
Reserved
0x4
16
0x5
Reserved
0x6
32
0x7
Reserved
0x8
64
0x9
Reserved
0xA
128
0xB
Reserved
0xC
256
0xD-0xF
Reserved
ADCSSTSHn is shown in
and described in
.
Return to
Figure 10-42. ADCSSTSHn Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
RESERVED
TSH3
TSH2
TSH1
TSH0
R-0x0
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
Table 10-37. ADCSSTSHn Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
RESERVED
R
0x0
15-12
TSH3
R/W
0x0
4th Sample and Hold Period Select.
The TSH3 field is used during the fourth sample of a sequence
executed with the sample sequencer.
11-8
TSH2
R/W
0x0
3rd Sample and Hold Period Select.
The TSH2 field is used during the third sample of a sequence
executed with the sample sequencer.
7-4
TSH1
R/W
0x0
2nd Sample and Hold Period Select.
The TSH1 field is used during the second sample of a sequence
executed with the sample sequencer.
3-0
TSH0
R/W
0x0
1st Sample and Hold Period Select.
The TSH0 field is used during the first sample of a sequence
executed with the sample sequencer.