ADC Registers
755
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Analog-to-Digital Converter (ADC)
10.5.20 ADCSSDC0 Register (Offset = 0x54) [reset = 0x0]
ADC Sample Sequence 0 Digital Comparator Select (ADCSSDC0)
This register determines which digital comparator receives the sample from the given conversion on
Sample Sequence 0, if the corresponding SnDCOP bit in the ADCSSOP0 register is set.
ADCSSDC0 is shown in
and described in
Return to
Figure 10-34. ADCSSDC0 Register
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
S7DCSEL
S6DCSEL
S5DCSEL
S4DCSEL
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
S3DCSEL
S2DCSEL
S1DCSEL
S0DCSEL
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
Table 10-27. ADCSSDC0 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-28
S7DCSEL
R/W
0x0
Sample 7 Digital Comparator Select.
When the S7DCOP bit in the ADCSSOP0 register is set, this field
indicates which digital comparator unit (and its associated set of
control registers) receives the eighth sample from Sample
Sequencer 0.
Values not listed are reserved.
0x0 = Digital Comparator Unit 0 (ADCDCCMP0 and ADCDCCTL0)
0x1 = Digital Comparator Unit 1 (ADCDCCMP1 and ADCDCCTL1)
0x2 = Digital Comparator Unit 2 (ADCDCCMP2 and ADCDCCTL2)
0x3 = Digital Comparator Unit 3 (ADCDCCMP3 and ADCDCCTL3)
0x4 = Digital Comparator Unit 4 (ADCDCCMP4 and ADCDCCTL4)
0x5 = Digital Comparator Unit 5 (ADCDCCMP5 and ADCDCCTL5)
0x6 = Digital Comparator Unit 6 (ADCDCCMP6 and ADCDCCTL6)
0x7 = Digital Comparator Unit 7 (ADCDCCMP7 and ADCDCCTL7)
27-24
S6DCSEL
R/W
0x0
Sample 6 Digital Comparator Select.
This field has the same encodings as S7DCSEL but is used during
the seventh sample.
23-20
S5DCSEL
R/W
0x0
Sample 5 Digital Comparator Select.
This field has the same encodings as S7DCSEL but is used during
the sixth sample.
19-16
S4DCSEL
R/W
0x0
Sample 4 Digital Comparator Select.
This field has the same encodings as S7DCSEL but is used during
the fifth sample.
15-12
S3DCSEL
R/W
0x0
Sample 3 Digital Comparator Select.
This field has the same encodings as S7DCSEL but is used during
the fourth sample.
11-8
S2DCSEL
R/W
0x0
Sample 2 Digital Comparator Select.
This field has the same encodings as S7DCSEL but is used during
the third sample.
7-4
S1DCSEL
R/W
0x0
Sample 1 Digital Comparator Select.
This field has the same encodings as S7DCSEL but is used during
the second sample.
3-0
S0DCSEL
R/W
0x0
Sample 0 Digital Comparator Select.
This field has the same encodings as S7DCSEL but is used during
the first sample.