Functional Description
802
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Controller Area Network (CAN) Module
\\tPhase1 = tPhase2
tTSeg1 = tProp + tPhase1
(41)
tTSeg1 = (1 × t
q
) + (4 × t
q
)
(42)
tTSeg1 = 5 × t
q
(43)
tTSeg2 = tPhase2
(44)
tTSeg2 = (Information Processing Time + 4) × t
q
(45)
tTSeg2 = 4 × t
q
(46)
\\Assumes IPT = 0
tSJW = 4 × t
q
(47)
\\Least of 4, Phase1, and Phase2
Table 11-5. CANBIT Register Values for Low Baud Rate
Example
Bit
Value
TSEG2
= TSeg2 – 1
= 4 – 1
= 3
TSEG1
= TSeg1 – 1
= 5 – 1
= 4
SJW
= SJW – 1
= 4 – 1
= 3
BRP
= Baud rate prescaler – 1
= 50 – 1
= 49
The final value programmed into the CANBIT register = 0x34F1.