![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 1457](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_10955781457.webp)
PWM Registers
1457
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Pulse Width Modulator (PWM)
Table 21-8. PWMINTEN Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
3
INTPWM3
R/W
0x0
PWM3 Interrupt Enable.
0x0 = The PWM generator 3 interrupt is suppressed and not sent to
the interrupt controller.
0x1 = An interrupt is sent to the interrupt controller when the PWM
generator 3 block asserts an interrupt.
2
INTPWM2
R/W
0x0
PWM2 Interrupt Enable.
0x0 = The PWM generator 2 interrupt is suppressed and not sent to
the interrupt controller.
0x1 = An interrupt is sent to the interrupt controller when the PWM
generator 2 block asserts an interrupt.
1
INTPWM1
R/W
0x0
PWM1 Interrupt Enable.
0x0 = The PWM generator 1 interrupt is suppressed and not sent to
the interrupt controller.
0x1 = An interrupt is sent to the interrupt controller when the PWM
generator 1 block asserts an interrupt.
0
INTPWM0
R/W
0x0
PWM0 Interrupt Enable.
0x0 = The PWM generator 0 interrupt is suppressed and not sent to
the interrupt controller.
0x1 = An interrupt is sent to the interrupt controller when the PWM
generator 0 block asserts an interrupt.