PWM Registers
1456
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Pulse Width Modulator (PWM)
21.5.6 PWMINTEN Register (Offset = 0x14) [reset = 0x0]
PWM Interrupt Enable (PWMINTEN)
This register controls the global interrupt generation capabilities of the PWM module. The events that can
cause an interrupt are the fault input and the individual interrupts from the PWM generators.
NOTE:
The "n" in the INTFAULTn and INTPWMn bits in this register correspond to the PWM
generators, not to the FAULTn signals.
PWMINTEN is shown in
and described in
Return to
Figure 21-12. PWMINTEN Register
31
30
29
28
27
26
25
24
RESERVED
R-0x0
23
22
21
20
19
18
17
16
RESERVED
INTFAULT3
INTFAULT2
INTFAULT1
INTFAULT0
R-0x0
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
15
14
13
12
11
10
9
8
RESERVED
R-0x0
7
6
5
4
3
2
1
0
RESERVED
INTPWM3
INTPWM2
INTPWM1
INTPWM0
R-0x0
R/W-0x0
R/W-0x0
R/W-0x0
R/W-0x0
Table 21-8. PWMINTEN Register Field Descriptions
Bit
Field
Type
Reset
Description
31-20
RESERVED
R
0x0
19
INTFAULT3
R/W
0x0
Interrupt Fault 3.
0x0 = The fault condition for PWM generator 3 is suppressed and
not sent to the interrupt controller.
0x1 = An interrupt is sent to the interrupt controller when the fault
condition for PWM generator 3 is asserted.
18
INTFAULT2
R/W
0x0
Interrupt Fault 2.
0x0 = The fault condition for PWM generator 2 is suppressed and
not sent to the interrupt controller.
0x1 = An interrupt is sent to the interrupt controller when the fault
condition for PWM generator 2 is asserted.
17
INTFAULT1
R/W
0x0
Interrupt Fault 1.
0x0 = The fault condition for PWM generator 1 is suppressed and
not sent to the interrupt controller.
0x1 = An interrupt is sent to the interrupt controller when the fault
condition for PWM generator 1 is asserted.
16
INTFAULT0
R/W
0x0
Interrupt Fault 0.
0x0 = The fault condition for PWM generator 0 is suppressed and
not sent to the interrupt controller.
0x1 = An interrupt is sent to the interrupt controller when the fault
condition for PWM generator 0 is asserted.
15-4
RESERVED
R