background image

For the competent person

Installation instructions

VRT 350f

VRT 350f

GB, IE

Installation instructions

Summary of Contents for VRT 350f

Page 1: ...For the competent person Installation instructions VRT 350f VRT 350f GB IE Installation instructions...

Page 2: ...r Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Telefon 49 21 91 18 0 Telefax 49 21 91 18 28 10 info vaillant de www vaillant de Vaillant GmbH 2012 These instructions or extracts thereof may only...

Page 3: ...er 14 5 2 Connecting the radio receiver unit installed in the living room 14 6 Start up 16 6 1 Overview of installation assistant set up options 17 7 Operating 18 7 1 Installer level overview 19 8 Ope...

Page 4: ...Contents 4 Installation instructions VRT 350f 0020131978_00 12 Customer service 32...

Page 5: ...s of the system These installation instructions are enclosed with the various system parts and supplementary components Furthermore observe all operating instructions enclosed with components of the s...

Page 6: ...must be installed by a qualified skilled tradesman who is responsible for compliance with the applicable re quirements regulations and directives Read through these installation instructions carefully...

Page 7: ...dged or disabled Immediately rectify any faults and damage that may af fect safety Install the controller in a location where it is not covered by furniture curtains or other objects If thermostatic c...

Page 8: ...ermissible with the following components and accessories Domestic hot water cylinder conventional Improper use Any other use or use beyond that specified shall be considered improper use Any direct co...

Page 9: ...1 Radio receiver unit 1 Wall mounting base for radio receiver unit 1 Wall mounting base for controller Quant ity Component 2 Fastening material 2 screws and 2 wall plugs 1 Battery set 4 x AA 1 3 way...

Page 10: ...io receiver unit from the wall mounting base 9 Alternatives 1 2 Conditions Vertical plug connections with pins in the electronics box If required remove the 3 way pin header Carefully press the radio...

Page 11: ...connected to the controller PCB The 3 way pin header is connected to the controller PCB Remove the 3 way pin header 2 Fit the radio receiver unit on an interior wall of the main living room in such a...

Page 12: ...nting hole 6 mm 7 Route the eBUS line through one of the cable ducts 4 8 Insert the wall plugs supplied 9 Use the screws supplied to secure the wall mounting base 10 Connect the eBUS line to the termi...

Page 13: ...m 6 Insert the rawl plugs supplied 7 Fix the wall mounting base 1 to the wall using the screws supplied 8 Locate the two bottom lugs of the finishing panel 3 in the holes in the wall mounting base 9 P...

Page 14: ...iver unit installed in the living room 5 2 1 Connecting the radio receiver unit to the boiler with a 3 4 5 Terminal 1 Switch off the boiler 2 Disconnect the power supply to the boiler 3 Disconnect the...

Page 15: ...from the power mains by pulling out the mains plug or de energising the boiler using a partition with a contact opening of at least 3 mm 4 Secure the power supply to the boiler against being switched...

Page 16: ...To be able use the controller to set the temper ature for the hot water generation and heating circuit you must set the maximum value for the temperatures on the boiler You can use the installation a...

Page 17: ...set up options Setting Values Increment select Default setting Setting Min Max Language Languages available for selection English Control strategy Two point analogue Two point Route adjustment1 5 5 1...

Page 18: ...controller has two operating levels the access level for the operator and the access levels for the competent person The setting and read out options for the operator the op erating concept and an op...

Page 19: ...level Enter code 000 999 1 000 Installer level Service information Enter contact details Installer 1 11 Figures A to Z 0 to 9 Space Phone number 1 12 Numbers 0 to 9 Space Hyphen Installer level Servi...

Page 20: ...urrent value HEATING 1 Auto day temp to Current value hr min Day temperature 5 30 0 5 20 Set back temp 5 30 0 5 15 Flow temp target Current value Actual flow temperature Current value Advancd functns...

Page 21: ...alue System Control strategy Current value 2 point analogue 2 point Plug adjustment1 5 5 1 0 RF connection Controller 0 10 1 Teach in On Off On Off Off Installer level Change code New code 000 999 1 0...

Page 22: ...ntroller 8 1 2 Entering the service date Menu Installer level Service information Service date In the controller you can save a date day month year for the next regular service When the date for the n...

Page 23: ...nstaller level System configuration System Control type Select this function to set the type of room temperature control Two point corresponds to an On Off control system Analogue corresponds to a mod...

Page 24: ...e day temperature Menu Installer level System configuration HEATING 1 Day temperature This function allows you to set the desired day temperat ure for the heating circuit 8 4 3 Setting the set back te...

Page 25: ...stic hot water Cylinder temp target This function allows you to define the set target temper ature for a connected domestic hot water cylinder de sired hot water temperature Set the set target tem per...

Page 26: ...of enclosed spaces outdoors the range is more than 100 m 8 6 2 Commissioning a replacement radio controller teach in Menu Installer level System configuration RF con nection Teach in You can use this...

Page 27: ...lay Press the right hand selector button to display a list of fault messages Note Not all error messages in the list appear automatically on the display Display Meaning Connected devices Cause Heat ge...

Page 28: ...y is dark Unit fault The power is switched off on at the heater Check the power supply for the heater No changes in the display via the rotary knob Unit fault The power is switched off on at the heate...

Page 29: ...Insert a screwdriver into the slot on the wall mounting base 2 Carefully lever the radio receiver unit from the wall mounting base 3 Dispose of the faulty radio receiver unit correctly 10 2 2 Removin...

Page 30: ...d radio re ceiver unit 10 3 4 Radio controller Activating teach in 1 On the controller select Menu Installer level System configuration RF connection Teach in 2 Set the parameter Teach in to ON As soo...

Page 31: ...emove the radio receiver unit from the boiler electronics box 3 If necessary close the front panel on the boiler 11 2 Removing the radio controller 1 Remove the radio controller from the wall Page 29...

Page 32: ...the transport packaging to the ap proved heating specialist company that installed the appli ance 12 Customer service To ensure regular servicing it is strongly recommended that arrangements are made...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...00 Vaillant Ltd Nottingham Road Belper Derbyshire DE56 1JT Telephone 0330 100 3461 Please contact Vaillant Service Solutions for further details 0330 100 3461 info vaillant co uk www vaillant co uk 27...

Reviews: