MII Management (EPHY) Registers
1049
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Ethernet Controller
15.7.2 EPHYBMSR Register (Address = 0x1) [reset = 0x7849]
Ethernet PHY Basic Mode Status - MR1 (EPHYBMSR)
This register reflects the basic mode features that are available in the EPHY.
EPHYBMSR is shown in
and described in
Return to
Figure 15-90. EPHYBMSR Register
15
14
13
12
11
10
9
8
RESERVED
100BTXFD
100BTXHD
10BTFD
10BTHD
RESERVED
R-0x0
R-0x1
R-0x1
R-0x1
R-0x1
R-0x0
7
6
5
4
3
2
1
0
RESERVED
MFPRESUP
ANC
RFAULT
ANEN
LINKSTAT
JABBER
EXTEN
R-0x0
R-0x1
R-0x0
R-0x0
R-0x1
R-0x0
R-0x0
R-0x1
Table 15-102. EPHYBMSR Register Field Descriptions
Bit
Field
Type
Reset
Description
15
RESERVED
R
0x0
14
100BTXFD
R
0x1
100Base-TX Full Duplex Capable.
0x0 = Device does not support 100Base-TX in full duplex mode.
0x1 = Device supports 100Base-TX in full duplex mode.
13
100BTXHD
R
0x1
100Base-TX Half Duplex Capable.
0x0 = The device does not support 100Base-TX in half duplex mode.
0x1 = The device supports 100Base-TX in half duplex mode.
12
10BTFD
R
0x1
10 Base-T Full Duplex Capable.
0x0 = The device does not support 10Base-T in full duplex mode.
0x1 = Device able to perform 10Base-T in full duplex mode.
11
10BTHD
R
0x1
10 Base-T Half Duplex Capable.
0x0 = Device not able to perform 10Base-T in half duplex mode.
0x1 = Device able to perform 10Base-T in half duplex mode.
10-7
RESERVED
R
0x0
6
MFPRESUP
R
0x1
Preamble Suppression Capable.
0x0 = The device does not perform management transactions with
preambles suppressed.
0x1 = The device performs management transactions with
preambles suppressed. For this mode, the 32-bits of preamble are
needed only once after reset, invalid opcode or invalid turnaround.
5
ANC
R
0x0
Auto-Negotiation Complete.
0x0 = Auto-Negotiation process not complete (either still in process,
disabled, or reset)
0x1 = Auto-Negotiation process complete.
4
RFAULT
R
0x0
Remote Fault.
0x0 = No remote fault condition detected.
0x1 = Remote Fault condition detected (cleared on read or by reset).
Fault criteria: Far End Fault Indication or notification from Link
Partner of Remote Fault.
3
ANEN
R
0x1
Auto Negotiation Enabled.
0x0 = Device is not able to perform Auto-Negotiation.
0x1 = Device is able to perform Auto-Negotiation.
2
LINKSTAT
R
0x0
Link Status.
0x0 = Link not established.
0x1 = Valid link established (for either 10 or 100Mbs operation).