![Texas Instruments SimpleLink Ethernet MSP432E401Y Technical Reference Manual Download Page 678](http://html1.mh-extra.com/html/texas-instruments/simplelink-ethernet-msp432e401y/simplelink-ethernet-msp432e401y_technical-reference-manual_1095578678.webp)
Read the encrypted/decrypted data
Authentication_result=AES_TAG_OUT_n
data_resuly=AES_DATA_IN_n
Write the next context in
Context data registers
AES_KEY_jn=xxxx
AES_IV_IN_n=xxxx
Read the context registers
contextResult=
AES_KEY_jn
Read interrupt status register
Int_status= AES_IRQSTATUS
Clear interrupt status
AES_IRQSTATUS [3:0] = 0x0
Enable interrupts
AES_IRQENABLE [3:0] = 0xF
Write Next Data
AES_DATA_IN_n=xxxx
Is interrupt caused
By context output even?
AES_IRQSTATUS [3]
CONTEXT_OUT = 0 x 1
Is interrupt caused
By context output even?
AES_IRQSTATUS [1]
DATA_IN = 0 x 1
Is interrupt caused
By context output even?
AES_IRQSTATUS [0]
CONTEXT_IN = 0 x 1
END
START
yes
yes
yes
no
no
no
AES Module Programming Guide
678
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
Advance Encryption Standard Accelerator (AES)
Figure 9-13. AES Interrupt Service