System Control
Table 4-172. PCHIB Register Field Descriptions
Bit
Field
Type
Reset
Description
31-1
RESERVED
R
0x0
0
P0
R/W
0x1
Hibernation Module Power Control. The Pn bit encodings do not
apply if the corresponding bit in the RCGCHIB, SCGCHIB, or
DCGCHIB register is clear.
0x0 = The HIB module is not powered and does not receive a clock.
In this case, the state of the module is not retained. This
configuration provides the lowest power consumption state.
0x1 = The HIB module is powered but does not receive a clock. In
this case, the module is inactive.