System Control Registers
231
SLAU723A – October 2017 – Revised October 2018
Copyright © 2017–2018, Texas Instruments Incorporated
System Control
Table 4-16. MISC Register Field Descriptions (continued)
Bit
Field
Type
Reset
Description
1
BORMIS
R/W1C
0x0
BOR Masked Interrupt Status
0x0 = When read, 0 indicates that a brownout condition has not
occurred. Writing 0 has no effect on the state of this bit.
0x1 = When read, 1 indicates that an unmasked interrupt was
signaled because of a brownout condition. Writing 1 to this bit clears
it and also the BORRIS bit in the RIS register.
0
RESERVED
R
0x0