background image

Introduction

The Warner Electric CBC-150 series is a family of clutch/
brake controls which conveniently mount to the conduit 
box cover of the Electro Module line of electromagnetic 
clutches and brakes. The CBC-150 series controls are 
dual channel devices available in two models:

 

CBC-150-1 

120 VAC input 

 

CBC-150-2 

220/240 VAC input

These controls are designed for operation of all Warner 
Electric 90 VDC clutches and brakes. They should not, 
however, be used to directly power Warner Electric 
permanent magnet failsafe brakes as these products 
require an adjustable current or voltage supply for 
optimum release. These controls indicate when the 
output channels are energized with LEDs

Suppression circuitry insures fast coil decay for 
rapid cycle rates. Customer provided switching is 
accomplished on the AC input to the control.

Specifications

Input

CBC-150-1:  120 VAC, 50/60 Hz, 1 phase, 200 VA max.

CBC-150-2:  220/240 VAC, 50/60 Hz, 1 phase, 200 VA max.

Output

CBC-150-1:  90 VDC full-wave rectified nominal,  

Dual channel, 0.8A max. per channel.

CBC-150-2:  90 VDC half-wave rectified nominal,  

Dual channel, 0.8A max. per channel.

Fusing

 (external to control, supplied by customer)

CBC-150-1:  2 amp, 125 V fast-blo
CBC-150-2:  2 amp, 250 V fast-blo; required on both legs.

Switching 

(Supplied by customer on AC input )

1. Electromechanical (SPDT) (or Two SPST)

 

CBC-150-1:  

Rated 120 VAC, 1 amp minimum

 

CBC-150-2:  

Rated 240 VAC, 1 amp minimum

2. Solid State (maximum leakage current < 2ma)

 

CBC-150-1:  

Rated 140 VAC, 2 amp minimum

 

CBC-150-2:  

Rated 280 VAC, 2 amp minimum

Ambient Temperature

-20° to +122°F (-29° to 50°C)

Reorder Information

Model 

Part Number

CBC-150-1 

6004-448-001

CBC-150-2 

6004-448-002

Conduit 

5370-101-042

Cycle Rate

In most applications, the maximum cycle rate is limited 
by the clutch and/or brake capability rather than by 
the control. To determine specific capabilities, consult 
the Application Engineering section of Warner Electric 
Catalogs, P-8586-WE, P-8587-WE, P-8588-WE, 
P-8589-WE, P-8590-WE or P-1264-WE. The following 
table lists those clutch/brake models which maximum 
cycle rate may be limited by this control.

Models Limited by Control

Maximum Cycle 

Rate 

(cycles/min)

PB/PC-500

250

SF-500, EP-500, PB-650, EB-650

220

SF-650, EC-650, EM-210

175

PB/PC-825, EB-825

130

SF-825, EP-825, PC-1000, EB-1000

100

SF-825 brg., EC-825, EC-1000

95

SF-1000, EP-1000, PB/PC-1225

70

SF-1225, PB/PC-1525, EB-1225, AT-205

50

SF-1525, EP-1525, EC-1225

40

SF-1525HT 

20

CBC-150 Series Clutch/Brake Controls

P-239-21-WE
819-0477

Installation and Operation Manual

Failure to follow these 

instructions may result in product damage, 
equipment damage, and serious or fatal injury to 
personnel.