6-2-(84)
Normal Serial Interface
Section 6-2
ECM Search (Settings Data)
Note
Mask figures cannot be registered.
Data
Details
Settings
data
16
Measurement image
0: Image 0
1: Image 1
17
Coordinate mode
0: After scroll, calibration OFF
1: Before scroll, calibration OFF
2: After scroll, calibration ON
3: Before scroll, calibration ON
18
Edge extraction mask size
0: 3
3
1: 5
5
19
Edge extraction lower limit (10 to 255)
20
Edge extraction upper limit (10 to 255)
21
Black/white reverse
0: OFF
1: ON
22
Accuracy
0: Normal
1: Precise
23
Model region X 1 (0 to 511) (See note.)
24
Model region Y 1 (0 to 483) (See note.)
25
Model region X 2 (0 to 511) (See note.)
26
Model region Y 2 (0 to 483) (See note.)
27
Reference X (0 to 511)
28
Reference Y (0 to 483)
29
Search region X 1 (0 to 511)
30
Search region Y 1 (0 to 483)
31
Search region X 2 (0 to 511)
32
Search region Y 2 (0 to 483)
33
Correlation judgement upper limit (0 to 100)
34
Correlation judgement lower limit (0 to 100)
35
X judgement upper limit (-9,999.999 to 9,999.999)
36
X judgement lower limit (-9,999.999 to 9,999.999)
37
Y judgement upper limit (-9,999.999 to 9,999.999)
38
Y judgement lower limit (-9,999.999 to 9,999.999)
39
Candidate level (0 to 99)
40
Reduction ratio (25 to 100)
41
Model skipping (0 to 9)
42
Search skipping (0 to 9)
43
Matching edges display
0: OFF
1: ON