5-(7)
Screen Display and Monitor
Section 5-3
The Display Settings Screen will be displayed.
3.
Change the settings for each item.
4.
Select End.
The settings will be registered and the screen in (2.) will return.
Image Status
Select the type of itmage to be displayed in the background.
System settings
End
Image status
Freeze(Before scroll)
Display image
Image size
Display results
Scene/mode
Overall judgement
Processing time
:
:
:
:
:
:
:
Image0
All
None
ON
ON
ON
Selection
Details
Through
The latest image taken by the Camera is displayed directly.
If measurement is performed using a Through display, the mea-
surement time will be increased by the amount of time from when
the measurement command is input until the image input starts.
This delay is included in the measurement time shown on the
Monitor and Run Mode screens.
Freeze* (before
scroll)
A still of the image taken by the Camera is displayed. This image
is updated when measurement is performed.
Select Freeze when measuring moving objects.
If position displacement compensation is set, an unscrolled
image is displayed. The region will be scrolled by the position dis-
placement amount.
Freeze (after
scroll)
A still of the image taken by the Camera is displayed. This image
is updated when measurement is performed.
Select Freeze when measuring moving objects.
If position displacement compensation is set, an image scrolled
the position displacement amount will be displayed.