2-16-(28)
EC Positioning
Section 2-16
CHECK
To Change Box Sizes:
• Increase the Length of long side and Length of short side.
• Increase the Long side distance and Short side distance.
When Box Is Chipped
• Reduce the lower limit of Length of long side and Length of short side.
1.
Select Box size.
The registration methods will be displayed.
2.
Select Input parameter.
The Input Parameter Settings Screen will be displayed.
3.
Make the settings for each item.
4.
Select End.
The settings will be registered and the screen in (1.) will return.
STEP 5: Registering Reference Positions
Register reference positions here to detect position displacement. Positions
can be inspected if the difference between the reference position and the mea-
surement position is obtained from a calculation.
SeeAlso
Refer to
&LUFOHV
for an outline.
Measurement conditions
Line conditions
Search region
Box size
Reference registration
Clear
Region0(Box)
Input figure
Input parameter
End
Input parameter
Long side
Short side
Length of long side
Length of short side
Long side distance
:
:
:
:
:
[100]
[ 50]
[ 80:120]%
[ 80:120]%
[ 80:120]%