1-(55)
Basic Operations
Section 1-6
1-6-3-7
Setting the Coordinate Mode
When outputting the defect position coordinates, select the type of coordi-
nates.
CHECK
If the coordinate mode is changed after the judgement conditions have been
set, the measurement results will change also. Change the judgement condi-
tions to enable correct measurement.
1.
Select Coordinate mode.
The Coordinate Mode Settings Screen will be displayed.
2.
Make the settings for each item.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Coordinate mode
Output coordinate:
After scroll
Calibration : OFF
End
Before scroll:Output made using the coordinate values before
position displacement compensation
After scroll*: Output made using the coordinate values after
position displacement compensation
Refer to 7-4 Terminology for differences between
output coordinates.
ON:
Output made using coordinate values set using calibration
OFF*:
Output made using Camera coordinate values
The asterisk (*) indicates the default setting.