2-5-(14)
Binary Position Compensation
Section 2-5
6.
Select OK.
The settings will be registered and the screen in (2.) will return.
CHECK
It is also possible to set the binary level so that measurement is performed
only for an intermediate density range.
STEP 2: Drawing Regions
When a measurement region is drawn, measurement is performed for the dis-
played image and the results are registered as the reference values (area,
center of gravity, and axis angle). This position becomes the reference position
for position compensation, so be sure to place the measurement object in the
correct position before drawing the measurement region.
The settings method is the same as for Gravity and area.
SeeAlso
Refer to page 2-5-(7).
STEP 3: Re-registering Reference Values
This operation is performed when only the reference values are to be re-regis-
tered.
When a measurement region is drawn, the measurement is performed for the
displayed image and the results are registered as the reference values. If the
re-registering function explained here is used, only the reference values for the
image currently displayed will be registered. The area, center of gravity, and
axis angle are registered for the reference values.
The settings method is the same as for Gravity and area.
SeeAlso
Refer to page 2-5-(9).
STEP 4: Setting the Judgement Conditions
Make settings for the area, center of gravity, and axis angle.
CHECK
Position Compensation Judgement Results and Scrolling
OK: Scroll will be performed.
NG: Scroll will not be performed. The overall judgement will be NG, regard-
less of the measurement result.
Judgement conditions
End
Area range (0 to 9,999,999.999)
Range of movement of the measurement object
in the X direction (-9,999.999 to 9,999.999)
Range of movement of the measurement object
in the Y direction (-9,999.999 to 9,999.999)
Rotation range of the measurement object (-180.000 to 180.000,
but only values between -90.000 and 90.000 will be output.)
: Measurement results for the displayed image
Use these values as a reference for setting upper and lower limits.
Range for an OK judgement
Area : 2035.000
[ 2000.000 :
247808.000]
Gravity X : 180.000
[ 0.000 : 511.000]
Gravity Y : 250.000
[ 0.000 : 483.000]
Axis angle : 75.000
[ -180.000 : 180.000]