5-(29)
Setting Conditions for Saving Measurement Images
Section 5-5
Switching Method
In Monitor Mode or Run Mode, press the SHIFT+Up/Down Keys to switch
between images.
CHECK
• When Display is set to Last NG, the display cannot be switched to stored
images. Change the display to Freeze or another display mode and then
use the SHIFT+Up/Down Keys to switch between images.
• When the image input processing items Camera image or Switch camera
are set to 2 or more units, use the Up and Down Keys to switch between
images.
Last 35 (Mem )
Last 34 (Mem )
Last 1 (Mem )
Last (Mem )
Image just after measurement
Last 2 (Mem )
Last * (Mem )
If the following conditions hold, the
number of stored images will not
exceed 34.
Image storage: Set to only NG
Last measurement was OK.
The image display status changes
depending on the settings under
SYS/Conditions.
+
SHIFT
+
SHIFT
+
SHIFT
+
SHIFT
+
SHIFT
+
SHIFT