6-2-(59)
Normal Serial Interface
Section 6-2
Note
If these settings are changed, one rectangular region will be set and any previ-
ously drawn figures will be deleted. This is true for regions 1 to 7 as well.
CHECK
Only the allocations for region 0 are listed here. Refer to the allocations for
region 0 to calculate the numbers for regions 1 to 7.
EC Defect (Measurement Data)
Note
These values are output in pixels regardless of the calibration setting. This is
true for regions 1 to 7 as well.
The following data is the inspection region parameters for defect (deviation).
264
Region 0
Deviation reference position X (0 to 511)
265
Deviation reference position Y (0 to 483)
266
Region 1
Large defect flag
0: OFF
1: ON
to
... (Same as for region 0)
770
Region 7
Large defect flag
0: OFF
1: ON
to
... (Same as for region 0)
852
Deviation reference position X (0 to 511)
853
Deviation reference position Y (0 to 483)
Data
Details
Data
Details
Measure-
ment
data
0
Judgement result
-2: Not measured.
-1: NG
0: OK
1
Region 0
Judgement
2
Defect width (See note.)
3
Defect length (See note.)
4
Gravity X
5
Gravity Y
6
Area
7
Number of labels
8
Region 1
Judgement
to
... (Same as for region 0)
50
Region 7
Judgement
51
Defect width (See note.)
52
Defect length (See note.)
53
Gravity X
54
Gravity Y
55
Area
56
Number of labels