2-19-(5)
EC Circle Count
Section 2-19
The greater the mask size, the more the variations in surrounding pixels can
be absorbed. Select 5
5 to ignore uneven edges.
CHECK
This function is even more effective if smoothing is used.
SeeAlso
Refer to
,QSXWWLQJ&DPHUD,PDJHV
and
)LOWHULQJ$JDLQ
(where smooth-
ing can be set to be executed twice).
1.
Select Extract edges.
The screen for setting edge extraction levels will be displayed.
2.
Set the upper and lower limits.
Right Key:
Increases the lowest digit by one.
SHIFT+Right Keys: Increases the value 10 times faster.
Left Key:
Decreases the lowest digit by one.
SHIFT+Left Keys:
Decreases the value 10 times faster.
Up and Down Keys: Switches between setting items.
3.
Select the mask size.
4.
Press the ENT Key.
The settings will be registered and the screen in (1.) will return.
1.EC circle count
Measurement image
Extract edges
Measurement conditions
Inspected region
Candidate radius
Judgement conditions
Detailed conditions
Coordinate mode
Extract edges
Mask:5x5
OK
Upper[255]
Lower[100]
:Change ENT:OK ESC:Back
Lower limit
Upper limit