5-(10)
Screen Display and Monitor
Section 5-3
Positions
Displays all the regions set to the unit that executed the measurement. Figures
drawing using OR are shown in solid lines and figures drawn using NOT are
shown in dash lines.
CHECK
If the image size is set to All and the Camera image or Switch camera settings
in the image input-related processing items are set to 2 or more, use the Up
and Down Keys to switch between images.
Results
Displays a list of judgement results for the set unit.
If the character size is set to Normal, 8 sets of results will be shown on one
screen. If the character size is set to Small, 32 sets of results will be shown on
one screen.
SHIFT + Right/Left Keys: Scroll through the unit numbers.
CHECK
If the image size is set to All and the Camera image or Switch camera settings
in the image input-related processing items are set to 2 or more, use the Up
and Down Keys to switch between images.
Details
Displays detailed information for each unit. Use the Up and Down Keys to
switch between units. The displayed data differs depending on the processing
item and some processing items have multiple Details Screens.
Use the SHIFT + Left/Right Keys to switch between Details Screens.
Refer to the explanation for each processing item for information on the
respective Details Screens.
0.Scn 0
MON
NG
67ms
Image 0 freeze
0.Camera image
OK
1.EC pos. comp
OK
2.Fine matching
NG
3.Fine matching
OK
4.Switch camera
OK
5.EC pos. comp
OK
6.Fine matching
OK
7.Fine matching
OK
0.Scn 0
MON
NG
67ms
Image 0 freeze