2-9-(20)
Circle Position Compensation
Section 2-9
STEP 1: Setting Measurement Conditions
Select the degree of the characteristic feature in the point extractions to use
for comparison.
The asterisk (*) indicates the default setting.
1.
Select Position compensation.
Mode
Details
Black *
Uses the low density (black) points.
White
Uses the high density (white) points.
Black defect
Compares the density with surrounding pixels and uses the
point with the largest difference (where the density decreases
suddenly).
White defect
Compares the density with surrounding pixels and uses the
point with the largest difference (where the density increases
suddenly).
Edge
Compares the density with surrounding pixels and uses the
point with the largest difference (where the density decreases/
increases suddenly).
Set the conditions for detecting
the feature on the circumference.
1.Circle pos. comp
Position compensation
Detailed conditions
Model reference