2-26-(8)
Label Data
Section 2-26
2-26-5
Measurement Screens
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for label
data.
SeeAlso
Refer to
6(&7,210RQLWRU0RGHDQG5XQ0RGH
for details on Monitor and
Run modes.
CHECK
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
Use the Up or Down Key to change to the unit for which label data is set and
the following detailed screens will be displayed.
:
: Image0
: All
:
Details
End
Image status
Freeze(Before scroll)
Display image
Image size
Display results
0.Scn 0
RUN
2.Label data
Judge : OK
Label no. : 2
Area : 561
Gravity X : 450.00
Gravity Y : 250.00
0.Scn 0 RUN OK 45ms
Judgement result for this Unit
A circle is displayed at the center of
gravity of the specified label for an OK
judgement; an ex, for a NG judgement.
Display Image
Binary image for Labeling
reference unit
Gray image for Fine Matching
or EC Defect reference unit