2-6-(37)
EC Position Compensation
Section 2-6
2-6-5
Measurement Screens
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for EC posi-
tion compensation.
SeeAlso
Refer to
6(&7,210RQLWRU0RGHDQG5XQ0RGH
for details on Monitor and
Run modes.
CHECK
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
Use the Up or Down Key to change to the unit for which EC position compen-
sation is set and the following detailed screens will be displayed.
Use the SHIFT+Right or Left Keys to switch in order between the four
screens.
Scroll Amount
Detailed Display
The measurement results for each region will be displayed.
:
: Image0
: All
:
Details
End
Image status
Freeze(Before scroll)
Display image
Image size
Display results
0.Scn 0
RUN
0.
0
1.EC pos. comp
Judge:OK
ScrollX:256.321
ScrollY:269.213
Scroll : 20.0
OK 45ms
0.Scn 0
RUN
Region number
Search region
1.EC pos. comp
Region0 Region1
Pos.X
295.667
Pos.Y
315.675
Angle 0.000
0
OK 45ms
0.Scn 0
RUN
Output coordinates