2-5-(18)
Binary Position Compensation
Section 2-5
2-5-4
Measurement Screens
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for binary
position displacement compensation.
SeeAlso
Refer to
6(&7,210RQLWRU0RGHDQG5XQ0RGH
for details on Monitor and
Run modes.
CHECK
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
Use the Up or Down Key to change to the unit for which binary position com-
pensation is set and the following detailed screens will be displayed.
Use the SHIFT+Right or Left Keys to switch in order between the three
screens.
Scroll Amount
Detailed Display
The measurement values for each region will be displayed.
:
: Image0
: All
:
Details
End
Image status
Freeze(Before scroll)
Display image
Image size
Display results
0.Scn 0
RUN
1.Binary pos. comp
Judge:OK
ScrollX:256.321
ScrollY:269.213
Scroll : 20.0
OK 45ms
0.Scn 0
RUN
Area : 1356.222
Grav. X: 256.321
Grav. Y: 269.213
1.Binary pos. comp
OK 45ms
0.Scn 0
RUN
Region 0 Region1