6-2-(65)
Normal Serial Interface
Section 6-2
EC Positioning (Settings Data)
Data
Details
500
Measurement image
0: Image 0
1: Image 1
501
Coordinate mode
0: After scroll, calibration OFF
1: Before scroll, calibration OFF
2: After scroll, calibration ON
3: Before scroll, calibration ON
502
Edge extraction mask size
0: 3
3
1: 5
5
503
Edge extraction lower limit (10 to 255)
504
Edge extraction upper limit (10 to 255)
505
Region 0
Search region upper left X (0 to 511)
506
Search region upper left Y (0 to 483)
507
Search region lower right X (0 to 511)
508
Search region lower right Y (0 to483)
509
Reference position X (0 to 511)
510
Reference position Y (0 to 483)
511
Reference angle (0 to 359)
The following settings data is for circle measurement.
Settings
data
512
Region 0
Circle color
0: Black
1: White
2: Both
513
Skipping
0: OFF
1: ON
514
Circular value (0 to 100)
515
Center X (0 to 511)
516
Center Y (0 to 483)
517
Circumference radius (3 to 512)
518
Circumference width (1 to 64)
519
Radius judgement upper limit (1 to 9,999.999)
520
Radius judgement lower limit (1 to 9,999.999)