2-14-(27)
Density Defects
Section 2-14
STEP 1: Drawing Measurement Regions
Draw a figure in the section to be inspected.
CHECK
Do not include areas with marks and patterns in the measurement region. It
will not be possible to distinguish them from surface detects, and measure-
ment will not be performed properly.
CHECK
Position detection can be also performed using algorithms for detecting
defects.
When a measurement region is drawn, measurement is performed for the dis-
played image and the results are registered as the reference values (X and Y
coordinates of the position where the defect was found). This position
becomes the reference position, so be sure to place the measurement object
in the correct position before drawing the measurement region.
1.
Select Density defect.
The settings selections will be displayed.
2.
Select Select region.
A list of region numbers will be displayed.
3.
Select the region number.
0.Scn 0=SET=
ENT:Set SFT+ESC:Edit
0.Camera image
1.Density defect
2.
1.Density defect
Measurement image
Select region
Coordinate mode
Select region
Region0
Region1
Region2
Region3
Region4
Region5
Region6
Region7