2-19-(13)
EC Circle Count
Section 2-19
2-19-6
Setting Judgement Conditions
Set the number of circles for an OK judgement.
1.
Select Judgement conditions.
The Judgement Conditions Settings Screen will be displayed.
2.
Set the conditions for an OK judgement.
3.
Select End.
The settings will be registered and the screen in (1.) will return.
Judgement conditions
End
Quantity : 6 [ 6: 6]
No. of circles for an OK
judgement (0 to 64)
Measurement result for
displayed image. Use as
reference for setting upper
and lower limits.
1.EC circle count
Measurement image
Extract edges
Measurement conditions
Inspected region
Candidate radius
Judgement conditions
Detailed conditions
Coordinate mode
Judgement conditions
End
Quantity : 6 [ 6: 6]