2-14-(34)
Density Defects
Section 2-14
2-14-4
Measurement Screens
Detailed measurement values can be displayed on the screen in Monitor and
Run modes. These values are useful when adjusting measurement conditions.
This section describes what kind of information can be displayed for density
defect inspections.
SeeAlso
Refer to
6(&7,210RQLWRU0RGHDQG5XQ0RGH
for details on Monitor and
Run modes.
CHECK
Press the SHIFT+ESC Keys on the Run Screen to access the following screen
and change Display results to Details.
Use the Up or Down Key to change to the unit for which density defect inspec-
tion is set and the following detailed screens will be displayed.
Use the SHIFT+Right or Left Keys to switch in order between the two
screens.
Measurement Region and Position Display
:
: Image0
: All
:
Details
End
Image status
Freeze(Before scroll)
Display image
Image size
Display results
0.Scn 0
RUN
1.Density defect
Judge:
NG
+
0
0.Scn 0 RUN
NG
45ms
Judgement result for this region
Inspection region displayed in OK
color for OK result and displayed in
NG color for NG result.
Defect position
Region number