6-2-(88)
Normal Serial Interface
Section 6-2
Labeling (Measurement Data)
Settings
data
80
Auto
Upper left X coordinate (0 to 511)
81
Upper left Y coordinate (0 to 483)
82
Lower right X coordinate (0 to 511)
83
Lower right Y coordinate (0 to 483)
84
Fixed 1st digit
Upper left X coordinate (0 to 511)
85
Upper left Y coordinate (0 to 483)
86
Lower right X coordinate (0 to 511)
87
Lower right Y coordinate (0 to 483)
88
Fixed 2nd digit Upper left X coordinate (0 to 511)
89
Upper left Y coordinate (0 to 483)
90
Lower right X coordinate (0 to 511)
91
Lower right Y coordinate (0 to 483)
92
Fixed 3rd digit
Upper left X coordinate (0 to 511)
93
Upper left Y coordinate (0 to 483)
94
Lower right X coordinate (0 to 511)
95
Lower right Y coordinate (0 to 483)
96
Fixed 4th digit
Upper left X coordinate (0 to 511)
97
Upper left Y coordinate (0 to 483)
98
Lower right X coordinate (0 to 511)
99
Lower right Y coordinate (0 to 483)
Data
Measure-
ment
data
0
Judgement result
-2: Not measured.
-1: NG
0: OK
1
Number of labels
2
Measured X
3
Measured Y
4
Area
5
Reference X
6
Reference Y
7
Reference area
8
Displacement X
9
Displacement Y
10
Difference area
Data
Details