6-2-(32)
Normal Serial Interface
Section 6-2
Switch Camera (Settings Data)
Change Filtering (Measurement Data)
Data
Details
Settings
data
16
Input Camera number (0 to 3)
17
Filtering (Image 0)
0: OFF 1: Weak smoothing 2: Strong smoothing
3: Dilate 4: Erosion 5: Median
6: Enhance edges 7: Vertical edges
8: Horizontal edges 9: Extract edges
18
Filtering (Image 1)
0 to 9: Same as filtering (Image 0)
19
Filter size (Image 0)
0: 3
3
1: 5
5
20
Filter size (Image 1)
0: 3
3
1: 5
5
21
BGS levels lower limit (Image 0) (0 to 255)
22
BGS levels upper limit (Image 0) (0 to 255)
23
BGS levels lower limit (Image 1) (0 to 255)
24
BGS levels upper limit (Image 1) (0 to 255)
25
Filtering order (Image 0)
0: Filtering
BGS levels
1: BGS levels
Filtering
26
Filtering order (Image 1)
0: Filtering
BGS levels
1: BGS levels
Filtering
Data
Details
Measure-
ment
data
0
Judgement result
0: OK
-2: Not measured.