2-15-(39)
EC Defect
Section 2-15
STEP 3: Setting Inspected Regions
1.
Select Inspected region.
The Inspected Region Settings Screen will be displayed.
2.
Set the region.
The method for drawing the region is the same as for removal regions.
SeeAlso
Refer to page 2-15-(13).
Once the region has been drawn, the screen in (1.) will return.
STEP 4: Setting Judgement Conditions
Set the ranges for the number of labels, area and center of gravity for an OK
judgement.
Inspected R0(Labeling)
Binary
Measurement conditions
Inspected region
Judgement conditions
Clear
Inspected region
New
End
Box
Ellipse
Circle
Circumference
Polygon
O
R
N O T
Judgement conditions
End
:
Number of labels 8
[ 0: 2500]
Judge area 2035.000
[ 0.000:247808.000 ]
Gravity X 26.000
[ 0.000: 511.000]
Gravity Y 157.000
[ 0.000: 483.000]
:
:
:
:
Ranges for an OK judgement
Range for number of labels in measurement region (0 to 2,500)
Range for specified label number area (0 to 9,999,999.999)
Range of movement in X direction for specified label number
(
-
9,999.999 to 9,999.999)
Range of movement in Y direction for specified label number
(
-
9,999.999 to 9,999.999)
Measurement results for the displayed image
Use these values as a reference for setting upper and lower limits.